Upgrade your ANYCUBIC I3 Mega or Mega-S 3D printer with this high-quality Ultrabase platform. Measuring 240x220x3mm, this platform comes equipped with..
This 25 in 1 screwdriver kit is perfect for all your DIY projects, whether you're working on electronics, appliances, or furniture. The magnetic bits ..
Get this set of 2 MGN12H linear guides with 2 slider guide rails to ensure smooth and precise linear motion in your projects. The rail length options ..
The 2WD Transparent Smart Motor Robot Car Battery Chassis Kit is perfect for Arduino enthusiasts looking to build their own robot car. This kit includ..
MAX30102 Heart Rate Sensor Module Pulse Detection Blood Oxygen Sensor Concentration Test Module for arduino STM32Description:The MAX30102 is an integrated pulse oximeter and heart rate monitor biosensor module. It integrates a red LED and an infrared..
MAX30102 Heart Rate Sensor Module Pulse Detection Blood Oxygen Sensor Concentration Test Module for arduino STM32
Description:
The MAX30102 is an integrated pulse oximeter and heart rate monitor biosensor module. It integrates a red LED and an infrared LED, a photodetector, an optical device and low-noise electronic circuits with ambient light suppression. The MAX30102 uses an 18V power supply and a separate 50V power supply for the internal LEDs. Wear the device for heart rate and blood oxygen collection, and wear it on your fingers, earlobe and wrist. The standard I2C compatible communication interface can transfer the collected values to Arduino, KL25Z and other microcontrollers for calculating heart rate and blood oxygen. In addition, the chip can also shut down the module through software, the sleep current is close to zero, and the power supply is always maintained. Due to its excellent performance, the chip is widely used in Samsung Galaxy S mobile phones. The chip integrates a glass cover to effectively eliminate external and internal light interference and provides the best reliable performance.
Setting:
Maximum LED wavelength: 660nm/880nm
LED supply voltage: 3.3-5V
Detection signal type: light reflection signal (PPG)
Output signal interface: I2C interface
Communication interface voltage: 18-3.3V-5V (optional)
Board reserved assembly hole size: 0.5 x 8.5mm
Working principle: Light dissolution method: measuring pulse rate and blood oxygen saturation using human tissue to cause different light transmission when the blood vessel beats; Light source: a wavelength-specific polar illumination tube, selective for oxyhemoglobin (HbO2) and hemoglobin (Hb) in arterial blood; The transmission is converted into an electrical signal: the volume of the arterial pulsation is changed into luminous transmission of light. At that time, the light is reflected by the human body tissues through photoelectric conversion, converted into an electrical signal and amplified and emitted.
Pin Description:
VIN: Main power input terminal 1.8V-5V; 3-bit pad: select the bus pull-up level, according to the pin main voltage, select 1.8V or 3.3V (this terminal contains 3.3V and above)
SCL: connect the I2C bus clock;
SDA: data connected to the I2C bus;
INT: MAX30102 chip interrupt pin;
RD: RED of MAX30102 chip, LED ground terminal, – generally not connected;
IRD: The MAX30102 chip's IR and LED grounding is generally not connected;
Feature:With signal output instructionsTTL output signal is low level0~5v analog voltage output, the higher the concentration, the higher the voltageC..
Product Overview:Sensitive material MQ- 4 gas sensors used in clean air, low conductivity tin oxide (SnO2). When there is an environment in which the ..
Product description:Sensitive material of MQ-5 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, ..
Feature:With signal output instructionsTTL output signal is low level0~5v analog voltage output, the higher the concentration, the higher the voltageC..
Product Overview:Sensitive material MQ- 4 gas sensors used in clean air, low conductivity tin oxide (SnO2). When there is an environment in which the ..
Product description:Sensitive material of MQ-5 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, ..
DESCRIPTIONThe MQ-6 module is used in gas leakage detecting equipment in family and industry, This module has high sensitivity to LPG, iso-butane, pro..
DESCRIPTIONThe MQ8 hydrogen sensor is designed to measure the concentration of hydrogen in the air, with a measurement range of 100 to 10,000ppm (part..
Product description:Sensitive material of MQ-9 gas sensor is SnO2, which with lower conductivity in clean air. It makedetection by method of cycle hig..
Module including an MQ2 sensor allowing the detection of several types of gas: LPG, Isobutane (C4H10), propane (C3H8), methane (CH4), hydrogen (H2), a..
The 100K Ohm NTC Thermistors come with a 1m cable, perfect for use in 3D printers. These thermistors are high quality and provide accurate temperature..
The 12864 Graphic LCD Smart Controller Display is a convenient accessory for RAMPS 1.4 boards, providing a user-friendly interface to control your 3D ..
This website uses cookies to enhance your experience and analyze site traffic. By continuing to browse, you agree to our use of cookies. Learn more in our Cookie Policy.